Data Center News > Blog > Power & Cooling > Sustainable Fire Protection in Data Centers | DCN
Power & Cooling

Sustainable Fire Protection in Data Centers | DCN

Last updated: January 29, 2024 8:17 pm
Published January 29, 2024
Share
The Increasing Viability of Sustainable Fire Protection in Data Centers
SHARE

In an increasingly digital society, the importance of secure data centers is growing by the day. A fire can cause devastating disruptions and outages, as the incident at hosting provider OVH in Strasbourg, France, a year ago has shown.

Holistic fire protection concepts are suitable for avoiding such disasters. Fire tests show that modern systems are not only reliable and economical, but also have a positive impact from an environmental and sustainability point of view.

Data Center Sustainability: Not Just an Energy Balance Issue

Related: Four Important Considerations When Selecting Fire Protection for Your Data Center

When developing modern data centers, which are growing rapidly in number and size, sustainability is becoming increasingly important. As part of a comprehensive sustainability assessment, in addition to the pure energy balance, other aspects must also be considered.

Direct factors, such as the materials and media used, have clear sustainability implications for data centers. As such, a carefully selected fire protection system can also make a valuable contribution to a facility’s sustainability profile.

Data Center Fire Risks and Their Consequences

Related: The State of Data Center Storage Cooling in 2023

In addition to the server rooms, data centers have numerous other technical areas that contain the infrastructure for operating IT. Since this power-hungry hardware generates an enormous amount of heat, it also poses a larger fire hazard. Moreover, uninterruptible power supply (UPS) and energy storage systems are now increasingly operated with lithium-ion batteries, which must meet high fire protection requirements.

The major fire that destroyed an OVH-cloud data center in Strasbourg, France, in the spring of 2021 shows the dramatic consequences of fire-related incidents. More than 65,000 customers were unable to access their data for days, and the cost of this incident is estimated at a value of more than €100 million ($106 million).

See also  Arrow Electronics and Schneider Electric collaborate

To ensure optimum fire protection of data centers, holistic solutions are required that take into account various fire requirements in a safe, ecological, and sustainable manner. Fire tests have demonstrated that effective sustainable fire protection is possible through the choice of extinguishing medium and the applied technology.

Holistic Solutions to Fighting Fire

In plant fire protection, we must deal with many technical areas, which, in themselves, have different risk potentials. This also applies to data centers. A closer look reveals that fire protection should not be limited to the server area. The following graphic illustrates how comprehensively ‘fire protection’ must be thought of in areas with increased fire risks such as data centers:

Fogtec

Data centers feature many technical areas that pose a high fire safety risk

In addition to areas with cable fire loads, liquid fires, and various medium fire hazard risks, lithium-ion batteries are of considerable importance due to their rapidly increasing use. To provide controlled protection against a (possible) fire event in data centers, early fire detection and firefighting systems must go hand in hand and be precisely coordinated.

High-Pressure Water Mist: A Sustainable Alternative

While conventional fire suppression systems consist of a mixture of different systems, high-pressure water mist (HPWM) systems can cover all fire and risk scenarios efficiently and demonstrably safely with just one central pump system. This includes the previously mentioned sensitive battery areas.

The primary purpose of a gas extinguishing system is to remove oxygen from the fire. However, a sealed room is required to be able to build up the required gas concentration. Consequently, structural overpressure relief must be created to maintain room integrity. In addition, once the system is triggered, the ventilation and consequently the servers must be shut down, which cannot be in the interests of the data center operators due to the lack of cooling.

See also  New energy asset management platform iON+ launches

Despite their widespread use to safeguard building integrity, conventional sprinkler systems are not the ideal choice here either, as they consume large quantities of water, causing considerable damage to electrical and electronic equipment. Massive impairments such as failures of servers, control cabinets, and controls for air conditioning and power supply in the data center would result. In addition, a sprinkler system requires a water supply of several 10,000 liters for at least 60 minutes of system operation, which blocks valuable space in the technical center.

An HPWM system, on the other hand, requires only about 10-20% of the water volume of a conventional sprinkler system, which guarantees minimal firefighting water damage. Generally, the local water supply can be accessed directly, eliminating the need for costly and space-intensive storage of water, since the pump system can easily be placed in small spaces. In addition, no other extinguishing agent can reduce temperatures so quickly and partially wash out smoke gases.

Sustainable Data Center Firefighting Technology

HPWM systems offer many advantages over conventional firefighting systems. When a high-pressure water mist system is triggered, the cost of restarting is limited to the cost of fresh water and the possible replacement of some nozzles.

Additional structural measures such as pressure relief and room sealing, on the other hand, can be saved, and thanks to the “pre-action” systems, false triggering and the unintentional escape of water are virtually eliminated.


Ralph Paulwitz is Head of Fixed System Sales at Fogtec Fire Protection

Source link

Contents
Data Center Sustainability: Not Just an Energy Balance IssueData Center Fire Risks and Their ConsequencesHolistic Solutions to Fighting FireHigh-Pressure Water Mist: A Sustainable AlternativeSustainable Data Center Firefighting Technology
TAGGED: Centers, data, DCN, Fire, Protection, sustainable
Share This Article
Twitter Email Copy Link Print
Previous Article earnings written on a pad of paper Earnings Roundup: How Major Data Center Players Fared in 1Q23 | DCN
Next Article Data Center Liquid Cooling is Moving from Niche to Mainstream Data Center Liquid Cooling is Moving from Niche to Mainstream | DCN
Leave a comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Your Trusted Source for Accurate and Timely Updates!

Our commitment to accuracy, impartiality, and delivering breaking news as it happens has earned us the trust of a vast audience. Stay ahead with real-time updates on the latest events, trends.
FacebookLike
TwitterFollow
InstagramFollow
YoutubeSubscribe
LinkedInFollow
MediumFollow
- Advertisement -
Ad image

Popular Posts

Cloudflare Expands Data, Serverless, and AI Tools | DCN

Cloudflare is rising the capabilities of its platform with an eye fixed on enabling builders…

April 9, 2024

Decentralised AI: Full of promise, but not without challenges

Decentralised synthetic intelligence has been hailed as one of the vital profound improvements of our…

August 27, 2025

Alif microcontrollers enable genAI on ultra-low-power edge devices

Alif Semiconductor introduced final week that it has launched benchmarks for its newest Ensemble E4,…

August 21, 2025

Intel Wins Almost $20B in Chips Incentives for US Plants | DCN

(Bloomberg) -- The US will award Intel Company $8.5 billion in grants and as a lot…

March 20, 2024

Ostrom Raises €20M in Series B Funding

Ostrom, a Berlin, Germany-based digital inexperienced power supplier, raised €20M in Sequence B funding. The…

June 21, 2025

You Might Also Like

Tokenization takes the lead in the fight for data security
AI

Tokenization takes the lead in the fight for data security

By saad
Siemens and nVent: pioneering liquid cooling solutions for AI data centres
Power & Cooling

Siemens and nVent: pioneering liquid cooling solutions for AI data centres

By saad
nVent electric unveils advanced liquid cooling solutions for data centres
Infrastructure

nVent electric unveils advanced liquid cooling solutions for data centres

By saad
Drax outlines 100MW data centre plan at Selby power station
Global Market

Drax outlines 100MW data centre plan at Selby power station

By saad
Data Center News
Facebook Twitter Youtube Instagram Linkedin

About US

Data Center News: Stay informed on the pulse of data centers. Latest updates, tech trends, and industry insights—all in one place. Elevate your data infrastructure knowledge.

Top Categories
  • Global Market
  • Infrastructure
  • Innovations
  • Investments
Usefull Links
  • Home
  • Contact
  • Privacy Policy
  • Terms & Conditions

© 2024 – datacenternews.tech – All rights reserved

Welcome Back!

Sign in to your account

Lost your password?
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.
You can revoke your consent any time using the Revoke consent button.